Alcatel Helium Leak Detectors:
ASI 20 MD
Description ASI 20 MD Advanced Modular Leak Detector for industrial applications. The ASI 20 MD is ideally suited for easy integration into any leak detection system, including hard vacuum and sniffing tests.
The ASI 20 MD is composed of three separate modules for maximum flexibility of integration, all 19'' rack compatible.
LACO is currently offering special pricing on select ASI 20 MD Leak Detectors. For more information, see our Specials page.
|
 |
|
 |
Features Gross and fine test modes
High inlet test pressure pressures (15 torr)
New generation analyzer cell with dual filaments
Modular design: a compact vacuum module, control panel, electronics module, rouging module (supplied separate)
Comprehensive I/O: RS232, 15 discrete I/O including vacuum and helium setpoints, 2 analog outputs
Multiple display modes
New floating auto zero feature
Powerful software designed for production leak
testing
Benefits High sensitivity (5.10-11 mbar.l/s)
A new analyzer cell equipped with dual filaments
Patented electron multiplier amplification system
A pure counterflow test mode with high cross over pressure (20 torr) for faster gross leak detection
A semi-counterflow test mode for better protection against helium build up inside the backing pump
A high cross over pressure in fine leak mode (2 torr) to eliminate effect of moisture on cycle time
A field proven molecular drag pump with intermediate port and the lowest rotational speed (27,000 rpm) on the market
An autocalibration system with a built-in temperature compensated calibrated leak
An advanced flat remote control panel with multiple displays
A mechanical design which allows multiple integration possibilities (multi position bracket) to optimize accessibility and reduce the distance between the leak detector and the test point
|
Applications LACO specializes in the integration of the ASI 20MD into your custom leak detection system. We can offer leak testing manifolds, software for testing and integration, or turn-key solutions for all your leak testing needs.
Specifations and Ranges Minimum detectable helium leak 5 x 10-11 atmcc/sec
Measurement range 10-11 to 10-2 atmcc/sec
Maximum test pressure 15 torr
Helium pumping speed at inlet depends on vacuum configuration
Pumping capacity (high vacuum) 7.5 l/s
Start-up time 2.5 min
Dimensions - Vacuum Module 18.5" x 9.8" x 5.2
Dimensions - Display Panel 19" 3U shallow rack
Dimensions - Electronic Module 19" 3U rack
|
|
Additional Information
ASI 20 MD Brochure (PDF)
|