CHALLENGE

  • Leak test gas pressurized missile steering system component using the fill gas
  • Have capabilities to test multiple part configurations with multiple gases
  • Method of calibrating the system
  • Operating in a clean-room environment

SOLUTION 

  • Single chamber RGA-based leak test system with PC-based control system
  • Multiple purge gases
  • Multiple calibrated leak manifold for system calibration using different gases
  • Customized data logging and report generation

SPECIFICATIONS

  • Test Method:  RGA refrigerant hard vacuum
  • Leak rate:  dependent on refrigerant
  • Throughput:  NA